Why the plasma power is not start working?

Q) The plasma power  is not starting when the CNC is in plasma mode, But if you set the CNC in flame mode the Plasma power source ignites.
 
A) The problem is caused because the CNC parameter is not set correct. Make sure in PLASMA parameters set the ARC ON M ORDER as 12 and ARC OFF M ORDER as 13. This should be set like this always never change.